2008 CITY OF HOUSTON COMMERCIAL ENERGY CONSERVATION CODE
CITY OF HOUSTON . COMMERCIAL ENERGY CONSERVATION CODE. Residential spaces include, but are not limited to, dwelling units, hotel/motel guest rooms, dormitories, nursing glazed swinging entrance doors and for revolving doors and ... Get Document
Harris County Fire Code Electronic Lock Procedures
Houston, TX 77092 713-316-3580 . Page 2 door numbers, sizes, and fire ratings of doors on which devices are to be installed. d. Contact Information - Building address, floor numbers, Entrance doors in buildings with an occupancy in Group A, B, ... View This Document
Attic Access Solutions For The New Building Codes
Attic Access Solutions for the New Building Codes Access doors from conditioned and doors Access doors from conditioned spaces to unconditioned spaces 2009 International Residential Code (IRC) Topic 2006 IRC 2009 IRC (page 469) Access ... View Document
FIBERGLASS SIZE SPECIFICATIONS 6'8 PRE-HUNG ENTRY DOOR UNITS
Inswing doors - to determine handing, view door from exterior left haleft handnd rright handight hand exterior exterior dec. 2010 fiberglass size specifications 6'8" pre-hung entry door units actual unit size rough opening size 8'0" pre-hung entry door units ... Fetch Content
ADA Door Compliance - 99 Doors, Front door Replacement ...
ADA Door Compliance 4.13 Doors. 4.13.1 General. Doors required to be accessible by 4.1 shall comply with the requirements of 4.13. 4.13.2 Revolving Doors and Turnstiles. Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route. ... Access Content
Doors, What Does The Building Code Require?
Doors, what does the Building Code require? By Martin Van Berlo, Emmet County Building Dept. Doors, every building has at least one. Without them, we couldn’t get in, or if we build around ourselves, ... Read Here
HOELSCHER WEATHERSTRIP MFG. CO., INC.
RESIDENTIAL APPLICATION Hoelscher Weatherstrip Manufacturing Company has been manufacturing and installing thresholds, The Hoelscher extruded aluminium threshold for in-swing doors has an additional feature that provides an extra measure of protection ... View Full Source
Dubai Skyscraper Catches Fire, Though No One Killed In Blaze
One of the world's tallest residential towers caught fire early Saturday in Dubai's Marina district, sending hundreds of residents pouring into the streets as bright yellow flames raged several stories high. No one ... Read News
ENERGY STAR Program Requirements For Residential Windows ...
ENERGY STAR Program Requirements for Windows, Doors, and Skylights: Version 5.0 (April 7, 2009) 1 ENERGY STAR ® Program Requirements for Residential ... Return Document
Fast Facts - Fire Safety Door - Compliance - Office Of Compliance
Office of Compliance Safety and Health FAST FACTS Proper Fire Doors and Improper Fire Door Openings At right is an example of a fire door that has ... View Document
Sliding Door: Analysis Sliding Doors
MEASUREMENT AND CFD ANALYSIS OF OPEN AIR INVASION PHENOMENON MEASUREMENT AND CFD ANALYSIS OF OPEN AIR INVASION PHENOMENON AT OPENING OF AN AUTOMATIC SLIDING DOOR Koji Sakai1, Hiroki Ono2, Masatoshi Ito3 sliding doors or revolving door layouts is conducted along with unsteady CFD analysis ... View Video
Fire Races Up High-rise Dubai Tower, But Claims No Lives
One of the world's tallest residential towers caught fire early Saturday in Dubai's Marina district, sending hundreds of residents pouring into the streets as bright yellow flames raged several stories high. No one ... Read News
CHAPTER 10 MEANS OF EGRESS
Entrance doors in a means of egress in buildings with an occupancyinGroup A,B,E,M,R-1or R-2and entrance tained within a single residential dwelling unit in Group R-2 or R-3 shall be permitted to be protected on the enclosed side with 0.5-inch (12.7 mm) ... View This Document
Building Code Clarifications - 10. Exiting - City Of Chicago
10.4 (13-160-250) Power-operated sliding doors . Per code section (13-160-250), The primary entrance to a tenant space within a multi-tenant office or mercantile In a corridor type residential building, except from the basement, 1. st. and 2. nd. ... Doc Retrieval
Loft Flooring Home: May 2013 - Blogspot.com
</span></a><br /><span>Even the popular web siteYouTube.com has seen the posting of numerous comedy skit videos and music videos about these elevators doors can look like apartment entrance doors. Loft Flooring Zone Houston; Loft Flooring Zone Brunswick; Loft Flooring ... View Video
Building Code Title 27 Subchapter 6 - Welcome To NYC.gov ...
Residential occupancy group J-3 and educational occupancy group G shall be exempt from this requirement. ARTICLE 4 NUMBER OF EXITS §[C26-603.1] Building entrance doors and other exterior exit doors shall be equipped with heavy duty lock sets ... Fetch This Document
Energy Code Compliance Guide To Window Selection In Texas
Energy Code Compliance Guide to Window Selection in Texas Code: 2006 International Energy Conservation Code This guide is designed to help select windows, doors and ... Access Doc
TEXAS DEPARTMENT OF INSURANCE
The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International Building Hoelscher Weatherstrip Manufacturing Co., Inc. 1011 Houston Oaks Divided Lite Wood Entrance Doors Test Standards ASTM E 330-02 ... Fetch Document
Entrances To And From For Electrical Equipment Rooms And
Electrical Code Requirements for Commercial and Residential Buildings Presented by Bob Nuzzi State Electrical Inspector 2005 NEC • Emergency Sources – A sign shall be placed at the service entrance equipment, at the meter location, ... View This Document
Sliding Door: Central Coast Sliding Doors
Sliding Aluminium Doors to: ENTRANCE PORCH Front Door to: ENTRANCE HALL fired central heating boiler. Door toREAR PORCH AND STORE ROOM window with views to the coast. BEDROOM TWO 4.57m x 4.43m (15'0" x 11'3") ... View Video
INSTALLATION INSTRUCTIONS For Pre-Hung Exterior Entry Doors ...
INSTALLATION INSTRUCTIONS for Pre-Hung Exterior Entry Doors (JII106) Newer construction methods have led to an increase in air and water tightness in buildings. ... Read Document
Bathroom Code For Showers And Bathtubs - Home Renovations ...
Three major points about bathroom code as concerns showers and bathtubs. About.com. Food. Southern Food; Barbecues & Grilling; Home Cooking; Cocktails; Because shower doors are usually glass and can break (and because of other access issues), ... Read Article
Sliding Door: Large Horizontal Sliding Doors
Friday, July 4, 2016 ... Read Article
City Of Houston Building Inspection CODE WORD 2003
City of Houston Building Inspection CODE WORD 2003 INTERPRETATIONS AND APPLICATIONS OF THE HOUSTON ADOPTED CODES 116 & Residential - R109 2003-39 Double Doors Signage Building – 1008.1.8.4 2003-40 Main exit doors Building – 1008.1.8.3 2003-41 ... Document Retrieval
No comments: